ABSTRACT

OBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. METHODS: This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. RESULTS: The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. CONCLUSIONS: The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.


OBJETIVO: Falhas da ventilação não-invasiva (VNI) têm sido relacionadas a efeitos adversos agudos do uso de máscaras. O objetivo deste estudo foi comparar a incidência, tipo e intensidade de eventos adversos e conforto das máscaras facial total (MFT), facial (MF) e nasal (MN). MÉTODOS: Estudo randomizado, tipo cruzado, em 24 voluntários sadios submetidos a seis períodos de VNI, modo bilevel positive airway pressure em ajustes de baixa e moderada a alta pressão. Foi aplicado um questionário de avaliação de onze eventos adversos especificamente relacionados ao uso das máscaras. O conforto foi avaliado por escala visual analógica. O CO2 exalado no circuito foi medido entre a conexão da máscara e o orifício de exalação. RESULTADOS: A MFT teve desempenho similar a MF e MN quanto a escores de conforto. A aplicação de pressões mais altas reduziu o conforto e aumentou a incidência e a intensidade dos eventos adversos, independentemente do tipo de máscara. A MFT teve melhor desempenho quanto a vazamentos e dor no nariz e pior resultado quanto ao ressecamento oronasal e claustrofobia. A MF teve o pior resultado quanto a vazamentos. A pressão parcial do CO2 exalado no circuito permaneceu em zero com a MFT. CONCLUSÕES: Os eventos adversos agudos causados pelas interfaces de VNI são relacionados ao tipo de máscara e aos parâmetros de pressão. A MFT é uma alternativa confiável às MF e MN. A reinalação de CO2 a partir do circuito é menos provável de ocorrer com a MFT.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Masks/adverse effects , Positive-Pressure Respiration/instrumentation , Respiratory Insufficiency/therapy , Acute Disease , Analysis of Variance , Cross-Over Studies , Equipment Failure Analysis , Masks/standards , Time Factors , Young Adult
2.
J. bras. pneumol ; 30(1): 26-38, jan.-fev. 2004. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-360090

ABSTRACT

INTRODUÇAO: Os exames de cultura e o exame bacterioscópico pelo método de coloração de Gram (GRAM) do aspirado traqueal ainda são objeto de controvérsias com relação ao diagnóstico etiológico na pneumonia associada à ventilação mecânica (PAV). OBJETIVO: Avaliar a concordância entre os resultados do GRAM e da cultura quantitativa do aspirado traqueal e do lavado broncoalveolar nos pacientes com PAV. MÉTODO: Foram estudados de modo prospectivo os pacientes internados no período de outubro de 2001 a agosto de 2002, que estavam há mais de 48hs sob ventilação mecânica, e que apresentavam suspeita clínica de PAV. No momento da suspeita clínica foi realizado o aspirado traqueal seguido do lavado broncoalveolar. O diagnóstico de PAV foi confirmado com a suspeita clínica associada à cultura quantitativa do lavado broncoalveolar 10(4)ufc/ml. RESULTADOS: Dos 119 pacientes sob ventilação mecânica, 32 (26,8 por cento) tiveram suspeita clínica de PAV, com confirmação diagnóstica em 25 (78 por cento) deles. A comparação entre o GRAM do aspirado traqueal e a cultura do lavado broncoalveolar mostrou uma moderada concordância (coeficiente de Kappa de 0,56). Houve concordância entre a cultura quantitativa do aspirado traqueal e do lavado broncoalveolar em 22/25 (88 por cento) e discordância em 3/25 (12 por cento) casos (coeficiente de Kappa de 0,71). A sensibilidade e a especificidade do aspirado traqueal para o diagnóstico de PAV com o ponto de corte 10 6 ufc/ml foram de 71 por cento e 72 por cento, respectivamente. CONCLUSAO: A combinação do GRAM com a cultura quantitativa do aspirado traqueal pode contribuir para a avaliação diagnóstica da PAV.


Subject(s)
Humans , Male , Female , Culture Media , Pneumonia, Bacterial/diagnosis , Pneumonia, Bacterial/microbiology , Respiration, Artificial/adverse effects , Bronchoalveolar Lavage Fluid/microbiology , Prospective Studies , Staining and Labeling , Trachea/microbiology
3.
Rev. bras. ciênc. saúde ; 4(1/3): 73-8, dez. 2000. ilus
Article in Portuguese | LILACS | ID: lil-281057

ABSTRACT

Os autores relatam um caso de teratoma maligno do mediastino (TMM) em um paciente jovem, assintomático, cuja investigação diagnóstica teve início após evidência de uma massa localizada no mediastino superior em uma radiografia convencional do tórax realizada durante internação no setor de Doenças Infecto-Contagiosas do Hospital Universitário Lauro Wanderley (DIC/HULW/UFPB), João Pessoa - Paraíba, devido a uma meningite bacteriana. Foram afastadas as hipóteses de tireóide ectópica e bócio mergulante. O diagnóstico diferencial com timoma se fez necessário. Os exames complementares realizados não foram esclarecedores e o diagnóstico definitivo foi confirmado através do anátomo-patológico após exérese do tumor. Os autores chamam a atenção para o interesse desse tipo de patologia para especialistas e clínicos gerais, uma vez que com o diagnóstico precose, a excisão cirúrgica do tumor pode mostrar-se curativa em certas lesões malignas


Subject(s)
Humans , Male , Mediastinal Neoplasms/diagnosis , Mediastinum , Teratoma/diagnosis